In this section, you will learn how to:
Adding an Insight Unit Individually
This method is best suited when each unit you want to monitor has a unique configuration or serves a distinct function within the facility. In such cases, the types and number of monitoring objects under each unit may differ significantly, making the use of a shared template unsuitable.
For example, a server room may require monitoring of several parameters such as temperature, humidity, and power usage. Similarly, a utility room might include water flow meters, pressure gauges, or air quality sensors. These variations necessitate a more tailored configuration.
Adding units individually enables you to define specific monitoring objectives per unit, select and assign relevant objects, and customize data thresholds, alert rules, or schedules that are unique to the unit.
- In the Main menu, under the ADMIN OPTIONS, in the Insight subsection, click Unit.
The Insight Unit page is displayed. - Click Add Insight Unit.
- Enter or select the required field information.
Field
Description
Name*
Enter a name for the unit.
Track
Select the task or rule to be applied for monitoring this unit.
Active
Select this checkbox to make this unit active.
Level
Displays the alert level of the unit as Observation, Warning, Serious, Critical and Missing Data.
Note: This field is displayed only after you have saved the unit.
Last State Updated
Displays the date and time when the data state for this unit was last updated.
Note: This field is displayed only after you have saved the unit.
Ignore Until
Displays the date until which the data state captured for this unit is to be ignored.
Note: This field is displayed only for units for which the Ignore Alarm feature has been enabled and is displayed only after you have saved the unit.
- Under Add Objects, enter or select the required field information.
Field
Description
Index*
Enter or select the Object Index to be monitored under this unit. This object index must match the index defined in the State Schema.
Building
Select the building where this object is capturing data.
Floor
Select the floor where this object is capturing data.
Desk
Select the desk for which this object is capturing data.
Room
Select the room for which this object is capturing data.
Area
Select the area for which this object is capturing data.
HVAC Zone
Select the HVAC zone for which this object is capturing data.
Lighting Zone
Select the lighting zone for which this object is capturing data.
Device
Select the device for which this object is capturing data.
Variable
Select the variable for which this object is capturing data.
Constant
Select the constant for which this object is capturing data.
AHU
Select the AHU for which this object is capturing data.
PAC
Select the PAC for which this object is capturing data.
UPS
Select the UPS for which this object is capturing data.
Breaker
Select the breaker for which this object is capturing data.
Energy Meter
Select the energy meter for which this object is capturing data.
Water Meter
Select the water meter for which this object is capturing data.
Access Device
Select the access device for which this object is capturing data.
- Click Add Object.
The object is added to the table. - To add more objects under this insight unit, repeat steps 4 and 5.
- Once all objects are added, click Save Unit.
The bulk addition method is ideal for configuring and monitoring multiple units that are structurally or functionally similar—such as workstations or meeting rooms. In such cases, it is unnecessary and inefficient to configure them individually. With this method, you can create a template that defines a standard set of monitoring objects and settings, then apply it to all relevant units in a single step. Any updates or modifications made to the template are automatically applied to all units configured using it.
- In the Main menu, under the ADMIN OPTIONS, in the Insight subsection, click Configuration.
The Insight Configuration page is displayed. - Click Tasks.
- Under the Action column, click the edit
icon for the task under which you want to create units. - Under the Unit Template section, click Add Unit Template.
- Enter or select the required field information.
Filter
Description
Name*
Enter a name for the template.
Entity Type*
Select the type of entity that the unit belongs to. For example, Desks, CCTV cameras, or HVAC units.
Unit Name*
Enter a placeholder representing the unit format, that will be replaced with the actual unit(s) when the template is run.
For example, ##Floor##-##NAME## will be replaced by 1st Floor – Desk 001, 1st Floor – Desk 002 and so on.
Building
Select the building where the unit(s) to be added using this template are installed.
Floor
Select the floor where the unit(s) to be added using this template are installed.
Schedule
Select how frequently the system should use the template to check for and create new units.
Active
Select this checkbox to make this template active.
Auto Deactivate
Select this checkbox to remove the deactivated units the next time this template is run.
- Click Save and then click Back to see the template added to the table.
- To trigger the template immediately, under the Action column, click Process.
The template runs and adds/removes units as per the configuration and displays them on the Insight Configuration page. - To edit the template, under the Action column, click the edit
icon. - Edit the fields as required and click Save.
The next time the template is run, all the units created with the template will also be modified.
Editing an Insight Unit Added Individually
- In the Main menu, under the ADMIN OPTIONS, in the Insight subsection, click Unit.
The Insight Unit page is displayed. - Under the Action column, click the edit
icon. - Edit the fields as required. Refer Adding an Insight Unit for field information.
- To edit an object under a unit, select any other parameter from the dropdown.
- To delete an object, under the Action column of the Object table, click the delete
icon. - Once you have made all the required changes, click Save Unit.